The T5 dyeing machine control computer is suitable for overflow machines, bobbin dyeing machines, loose fiber dyeing machines, etc. It adopts an integrated design and uses relay control for output, making it very convenient for installation. It adopts button operation, which is simple and hassle-free. The T5 features high control sensitivity and stability. It is connected to the Tianfu central control system via Ethernet communication to achieve centralized control and management.
Characteristics
1. 640×480 5.7 "color display screen
2. Full keyboard operation
3. The interface is intuitive and easy to operate
4. Quick menu
5. Multi-level password protection
6. USB flash drive backup and upgrade. Process programs and control parameters can be uploaded/downloaded/copied and backed up
7. It provides manual operation buttons to enable manual control operations on the computer
8. It has the function of "post-sampling" addition and additional programs
9. It has the functions of water inlet according to water volume, water level, yarn layer, and bath ratio
10. It offers multiple water inlet/outlet options and multiple overflow water washing methods
11. It simultaneously allows for the customization of switch quantities and analog quantities, as well as the customization of the company logo/name, water type name, alarm name, and status display window
12. It is capable of controlling both the material cylinder and the main cylinder, and it has the functions of fabric cycle control, fabric head search, and pH value measurement and control
13. It can be switched between Chinese and English for display
Technical parameters and function description
Name | T5 |
Control system | With the latest embedded hardware and software design |
Display mode | 640×480 5.7 "color display screen |
Storage process | Process program capacity 100, program step 200 steps |
Monitor communication | The RS485 communication interface is adopted to connect to the general brand PLC, and the Ethernet communication interface is adopted to build the central control system |
Temperature control mode | Switching type and proportional type are available for selection, which can realize switching type heating/cooling, proportional type heating/cooling, and proportional heating/switch cooling, and the maximum deviation is ≤1 ℃. |
Feeding mode | Switch/proportional type dosing (built-in 9 feeding curve), circulating dissolving/feeding, cleaning tank and other functions |
Bath ratio control | Using sensors such as flow meters and liquid level transmitters, it can automatically control the water input according to the weight of the cloth (yarn) or the height of the yarn layer, including the water level inflow, the bath ratio inflow, the water volume inflow, and the memory inflow. |
Input signal | PT100 analog signals 2 channels, 4-20mA current signals 3 channels, pulse signals 2 channels |
12-channel switch input signal, main tank, the switch signal of high, medium and low water level in dosing tank 1, and main pump fault, blocking cloth, central control contact and other switching signals, through the switch input (drain input) ) | |
Output signal | 3-channel 4-20mA current signal for proportional control of output control main pump, guide cloth, proportional heating/cooling valve, proportional feeding valve |
16-channel switch output signal . The switch output is connected to the PLC output through relay and TF9000P type communication interface, which realizes various functions such as water inlet, drainage, main pump, heating/cooling, overflow, alarm and calling, etc. | |
Information inquiry | It can store curve records for 20 days (0-24 hours), including temperature, water level, fabric head, PH value curves, 60 dyeing batches, as well as water, electricity and gas energy consumption data statistics for 6 months, 30 days or 30 processes, and 100 abnormal alarm records |
Define function | Company LOGO, company name, status Windows (5), switch input/output, analog input/output, batch parameter items, water type name, call/alarm name and other custom Settings, as well as control functions and control menu hide display custom Settings |
Operating conditions | Operating voltage:180-260VAC 50HZ ± 5% ,Operating voltage:≤40W;operating temperature0℃-50℃ |
Dimensions | 215mm(width) ×265mm (height) ×105mm(depth) |
Opening size | 185mm(width) ×238mm (height) |